Instruction manual
Installation
51
EN
Apply insulating material to the thread of
connector 3, then tighten the steel hose 4 to
the connector 3.
Connection to LPG
Use a pressure regulator and make the
connection on the gas cylinder following
the guidelines set out in the standards in
force.
The supply pressure must comply with the
values indicated in the table in “Gas types
and Countries”.
Room ventilation
The appliance should be installed in rooms
that have a permanent air supply in
accordance with the standards in force. The
room where the appliance is installed must
have enough air flow for the regular
combustion of gas and the necessary air
change in the room itself.
The air vents, protected by grilles, must be
the right size to comply with current
regulations and positioned so that no part
of them is obstructed, not even partially. The
room must be kept adequately ventilated in
order to eliminate the heat and humidity
produced by cooking: In particular, after
prolonged use, you are recommended to
open a window or to increase the speed of
any fans.
Extraction of the combustion products
The combustion products may be extracted
by means of hoods connected to a natural
draught chimney whose efficiency is certain
or via forced extraction. An efficient
extraction system requires precision
planning by a specialist qualified in this
area and must comply with the positions
and clearances indicated by the applicable
standards.
This domestic appliance is not
connected to a device for
extracting combustion products. It
must be installed and connected in
accordance with current
installation regulations. Pay
particular attention to the relevant
requirements regarding ventilation.