Instruction manual
Installation
52
When the job is complete, the installer must
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
Air
Combustion products
Extractor fan
5.5 Adaptation to different types of gas
If other types of gas are to be used, the
nozzles must be replaced and the primary
air must be adjusted. The hob has to be
removed in order to replace the nozzles
and adjust the burners.
Removing the hob top
1. Remove the burner caps and then
remove the pan supports by lifting one of
the two horizontal spokes.
2. Remove the knobs.