Instruction manual
Installation
55
EN
After having set the distance of the air
regulator “D”, the flame may appear as
illustrated:
• 1: the flame is “noisy” and “detaches”
from the burner: the air regulator has
been opened too far.
• 2: the flame is opaque, dull or has
yellow tips and “wraps around” the
burner: the air regulator has been closed
too far.
• 3: the flame is light blue, clear and
stable, does not “detach” or “wrap
around” the burner: the air regulator is
adjusted correctly.
If the flame appears as in “1” or “2”, the air
regulator has to be reset according to the
measurements shown in the table “Burner
and nozzle characteristics table”.
Adjusting the minimum setting for natural
or town gas
1. Light the burner and turn it to the minimum
position.
2. Extract the gas cock knob and turn the
adjustment screw next to the gas cock
spindle (depending on the model) until
the correct minimum flame is achieved.
3. Refit the knob and verify that the burner
flame is stable.
4. Turn the knob rapidly from the maximum
to the minimum setting: The flame should
not go out.
5. Repeat the operation on all gas cocks.