74 - INSTALLATION 914779617/A
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
regulations.
For the Australian/New Zealand market:
The circuit breaker incorporated in the fixed
connection must comply with AS/NZS 3000.
Connection with plug and socket
Make sure that the plug and socket are of the
same type.
Avoid using adapters, gang sockets or shunts as
these could cause overheating and a risk of
burns.
Cable replacement
1. Unscrew the screws on the rear casing.
2. Lift the rear casing slightly and remove it to
gain access to the terminal board.
3. Replace the cable.
4. Make sure that the cables (for the oven or
any hob) follow the best route in order to
avoid any contact with the appliance.
C = Position of the power cable.
Positioning
Removing the rear hook
Before fitting the appliance, the cable hook on
the rear cover must be removed using a pair of
scissors or a special tool.
Front panel seal
Glue the supplied seal to the rear part of the
front panel to avoid water or other liquids from
leaking in.
Fastening bushings
1. Remove the bushing covers on the front of
the appliance.
2. Mount the appliance into the recess.
3. Secure the appliance to the cabinet using
screws.
4. Cover the bushings with the previously removed covers.
Power voltage
Danger of electrocution
• Disconnect the mains power supply.
See General safety instructions.