User manual

Important Safety Instructions
12
1. door (bent)
2. hinges and latches (broken or
loosened)
3. door seals and sealing surfaces.
(d) The oven should not be adjusted
or repaired by anyone except
properly qualified service
personnel.
Precautions To Be Observed
Before And During Servicing To
Avoid Possible Exposure To
Excessive Microwave Energy
(a) Do not operate or allow the oven
to be operated with the door
open.
(b) Make the following safety checks
on all ovens to be serviced
before activating the magnetron
or other microwave source, and
make repairs as necessary:
1. interlock operation
2. proper door closing
3. seal and sealing surfaces (arcing,
wear, and other damage)
4. damage to or loosening of hinges
and latches, evidence of dropping
or abuse)
(c) Before turning on microwave
power for any service test or
inspection within the microwave
generating compartments, check
the magnetron, wave guide or
transmission line, and cavity for
proper alignment, integrity and
connections.
(d) Any defective or misadjusted
components in the interlock,
monitor, door seal, and
microwave generation and
transmission systems, shall be
repaired, replaced, or adjusted
by procedures described in this
manual before the oven is
released to the owner.
(e) A microwave leakage check to
verify compliance with the
Federal performance standard
should be performed on each
oven prior to release to the
owner.