Instruction manual
50 - CLEANING AND MAINTENANCE 91477A296/A
(the reservoir contains about 800 ml of
water).
fig. 3
7. At the end, remove the funnel and place the
loading drawer back in its place.
fig. 4
8. Close the door.
9. Touch the CONFIRM button to confirm
that you have finished filling the reservoir.
The appliance starts the function using the
parameters set.
Cleaning the water circuit
• During this process, the overflowing of water
inside the oven cavity is not intended as a
malfunction, rather it is part of the rinsing
procedure.
End of hydraulic circuit cleaning
10.At the end of the cleaning process, the
display indicates the request to drain water.
11.Clean and dry any residual water inside the
oven cavity.
Reservoir draining
12.Place the deep pan on the third shelf from
the bottom. Push it against the rear wall of
the oven cavity.
13. Touch the START button to start
draining the water into the jug.
The water starts to flow into the deep pan from
the drain pipe on the right side of the rear wall
of the oven cavity.
fig. 5
14.Wait for the end of the drain flow.
When finished, the reservoir indicator light
(in the information area on the right) and
the display indicate the end of the residual
water draining process.
15. Touch the CONFIRM button .
16. Drain the water from the deep pan.
Use cold tap water which is not too
hard, softened water or still mineral
water.
Do not use distilled water, tap water
with a high chloride content (> 40 mg/
l), or other liquids.
It is recommended to carry out the
cleaning process of the reservoir and
the hydraulic circuit a couple of times.
A cleaning solution can also be used
instead of water. In this case it is
advisable to carry out at least a couple
of water rinses afterwards, following the
instructions in this chapter.