User manual
Installation
27
EN
• Connect the gas supply line to the unit
pressure regulator using a 1/2” flex gas
line connector between the manual shut-
off valve and the pressure regulator. A
metal flex line or fixed metal pipe must
be used to connect the gas to the
appliance. If a metal gas line cannot be
used, consult your local certified
electrician or local electric codes for
proper grounding.
• Check the supply line connections for
leaks using a soap solution or non-
corrosive leak detection fluid. Do not use
a flame of any sort.
1. Turn on gas.
2. Apply a soap solution or non-corrosive
leak detection fluid to all joints and
fittings in the gas connection between the
shut-off valve and the cooktop. Include
gas fittings and joints in the cooktop if
connections may have been disturbed
during installation. Bubbles appearing
around fittings and connections indicate
a leak.
3. If you detect a leak, turn off the supply
line gas shut-off valve and tighten
connections.
4. Retest for leaks by turning the gas supply
line shutoff valve on. When the leak
check has been completed (no bubbles
appear), the test is complete.
5. Wipe off all residues of the soap solution
or detection fluid.
Important notes for Gas Connection
• The appliance and its individual gas
shutoff valve must be disconnected from
the gas supply piping system during
pressure testing of the system at test
pressures in excess of 1/2 psi (3.5kPa).
• The appliance must be isolated from the
gas supply piping system by turning off
its individual manual shut-off valve during
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psi (3.5kPa).
Final operations
• Completely fill out the conversion label
(part no. 92849A078) and attach it to
the rear of the appliance. Do not cover
any other labels with the conversion
label.
• Over time, the gas taps may become
difficult to turn and jam. Clean them
internally and replace the lubrication
grease.
WARNING
Install a gas shutoff valve near the
appliance. After installation, it must be
easily accessible in an emergency.
NOTE: Lubrication of the gas taps
should be performed by a
specialized technician.