Installation Instructions

Installation
20
4. Retest for leaks. If no bubbles appear,
the test is passed. Wipe off all residues
of detection fluid.
Testing the electric ignition of the
burner
This test should be performed after the
range and supply line connectors have
been carefully checked for leaks and the
range connected to the electric power
supply:
1. Push in and turn a surface burner knob to
the low flame position. You will hear the
igniter sparking.
2. The surface burner should light when gas
is supplied to the cooktop burners. Each
burner should light within four (4)
seconds, after air has been purged from
supply lines. Visually check that burner
has lit.
3. Once the burner lights, the control knob
should be rotated out of the low flame
position.
4. There are separate ignition devices for
each burner. Try each knob separately
and together until all burner valves have
been checked.
Minimum adjustment for natural Gas
Light the burner and turn the knob to the
minimum position. Remove the gas tap knob
and turn the adjustment screw at the side of
the tap rod until the desired minimum flame
is achieved. Refer to the following pictures.
Dual Flame burner:
•Rapid burner:
Refit the knob and verify the correct ignition
and burner flame stability (when turning the
knob rapidly from the maximum to the
minimum position the flame must not go out).
Repeat this operation on the remaining gas
taps on the cooktop.