Operation Manual
24
5.8.3 Modellen: SWT260 SWT260M
Set1
PROGRAMMA
VOORWASSEN
WASSEN
(°C/duur)
WARME
TUSSENSPOELIN
G
EINDSPOELING
(°C/duur)
FUNCTIE REPEAT
ACTIVEERBAAR
FUNCTIE
AUTO-OPEN
WEERGEGEVEN DUUR CYCLUS *
ALS ALTERNATIEF
VOOR AUTO-OPEN
ALS ALTERNATIEF
VOOR REPEAT
MET ACTIEVE
REPEAT
STANDAARD
Pr 01
-
45° /1’
-
55° /1’
(X)
(X)
6
8
Pr 02
-
55° /2’
-
62° /1’
(X)
(X)
9
11
Pr 03
-
60° /2’
-
65° /1’
(X)
(X)
11
13
Pr 04
X(**)
65° /5’
-
70° /1’
-
X
-
25
Pr 05
-
60°/5’
SI
93° /5’
-
X
-
31
Pr 06
X(**)
65°/5’
SI
93°/ 10’
-
X
-
44
Pr 07
X(**)
-
-
-
-
-
-
7
Set2
PROGRAMMA
VOORWASSEN
WASSEN
(°C/duur)
WARME
TUSSENSPOELIN
G
EINDSPOELING
(°C/duur)
FUNCTIE REPEAT
ACTIVEERBAAR
FUNCTIE
AUTO-OPEN
WEERGEGEVEN DUUR CYCLUS *
ALS ALTERNATIEF
VOOR AUTO-OPEN
ALS ALTERNATIEF
VOOR REPEAT
MET ACTIEVE
REPEAT
STANDAARD
Pr 1
-
45° /1’
-
55° /1’
(X)
(X)
6
8
Pr 2
-
55° /2’
-
62° /1’
(X)
(X)
9
11
Pr 3
-
60° /2’
-
85° /1’
-
X
-
17
Pr 4
X(**)
65° /5’
-
85° /5’
-
X
-
32
Pr 5
-
60°/5’
X
93° /5’
-
X
-
31
Pr 6
X(**)
65°/5’
X
93°/ 10’
-
X
-
44
Pr 7
X(**)
-
-
-
-
-
-
7
Opmerking: uitgezonderd de fasen aangegeven met ** komt het water altijd via de warmwaterleiding van het waternet –
wanneer er geen warm water beschikbaar is wordt koud water gebruikt en zal de duur van de cyclus langer zijn dan
aangegeven