Instruction manual
Installation
95
EN
Carefully screw the hose connector 3 to the 
appliance’s gas connector 1 (½” thread 
ISO 228-1), placing the seal 2 between 
them. The hose connector 4 can also be 
screwed to the hose connector 3, 
depending on the diameter of the gas hose 
used. After having tightened the hose 
connector(s), push the gas hose 6 onto the 
hose connector and secure it with the clamp 
5 that is compliant with the standard in force.
Connection with a steel hose
Make the connection to the gas mains 
using a continuous wall steel hose whose 
specifications comply with the applicable 
standard.
Carefully screw the connector 3 to the gas 
connector 1 of the appliance, placing the 
seal 2 between them.
Connection with a steel hose with 
bayonet fitting
Carry out the connection to the gas mains 
using a steel hose with bayonet fitting 
compliant with B.S. 669. Apply insulating 
material to the thread of the gas hose 
connector 4 and then tighten the adapter 3. 
Screw the assembly to the movable 
connector 1 of the appliance, placing the 
supplied seal 2 between them.
Connection using a rubber hose 
complying with current standards is 
only permitted if the hose can be 
inspected along its entire length.
The inside diameter of the hose 
must be 8 mm for LPG and 13 mm 
for Natural gas and Town gas.