Instruction manual
Installation
97
EN
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
 Air
 Combustion products
 Extractor fan
5.2 
Adaptation to different types of gas
In case of operation with other types of gas, 
the burner nozzles must be changed and 
the minimum flame adjusted on the gas 
cocks.
Replacing nozzles
1. Remove the grids, burner caps and 
flame-spreader crowns to access the 
burner cups.
2. Replace the nozzles using a 7 mm 
spanner according to the gas to be used 
(see Gas types and Countries).
3. Replace the burners in their respective 
housings.
1. External nozzle
2. Internal nozzle