Instruction manual
Installation
98
Adjusting the minimum setting for natural 
or town gas
Light the burner and turn it to the minimum 
position. Extract the gas cock knob and turn 
the adjustment screw next to the tap rod 
(depending on the model) until the correct 
minimum flame is achieved.
Refit the knob and verify that the burner 
flame is stable. Turn the knob rapidly from 
the maximum to the minimum setting: The 
flame should not go out. Repeat the 
operation on all gas cocks.
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the 
tap rod clockwise all the way.
Lubricating the gas cocks
Over time the gas taps may become difficult 
to turn and get blocked. Clean them 
internally and replace the lubrication grease.
Following adjustment to a gas 
other than the one originally set in 
the factory, replace the gas setting 
label on the appliance with the 
one corresponding to the new gas. 
The label is inserted inside the 
nozzle pack (where present).
Lubrication of the gas cocks should 
be performed by a specialised 
technician.