FAQ

GB
Make the connection to the gas mains using a continuous wall flexible steel pipe
whose specifications comply with the current regulations. Carefully screw the
connector
3
to the gas connector
1
of the appliance, placing the seal
2
between
them.
IT
Make the connection to the appliance using flexible bayonet style hose in accordance
to B.S. 669. The hose connection at the rear of the appliance has a 1/2" BSP external
thread. Apply a suitable sealing substance to the thread of the gas pipe connector
4
and then tighten the adapter
3
to it as shown in the figure. Screw this assembly to the
moveable connector
1
of the appliance, placing the seal
2
between them.
Make the connection to the gas mains using a continuous wall flexible steel pipe
whose specifications comply with the current regulations. Carefully screw the
connector
3
to the gas connector
1
of the appliance, placing the seal
2
between
them. Apply a suitable sealing substance to the thread of the connector
3
and then
tighten the flexible steel pipe
4
to the connector
3
.
IT
Make the connection to the gas mains using a rubber hose whose specifications
comply with the current regulations (verify that the reference standard is stamped on
the hose). Carefully screw the hose connector
3
to the gas connector
1
of the
appliance, placing the seal
2
between them. Push the rubber hose
5
onto the hose
connector
3
and secure it with the clamp
4
that is compliant with the applicable
standard.
IT
Make the connection to the gas mains using a rubber hose whose specifications
comply with the current regulations (verify that the reference standard is stamped on
the hose). Carefully screw the hose connector
3
to the gas connector
1
of the
appliance, placing the seal
2
between them. The hose connector
4
can also be
screwed to the hose connector
3
, depending on the diameter of the gas pipe used.
After having tightened the hose connectors, push the gas pipe
6
onto the hose
connector
3
or
3
+
4
and secure it with the clamp
5
that is compliant with the applicable
standard.
IT
Connection using rubber hoses complying with the current regulations is only
permitted if the hose can be inspected along its entire length.
After each intervention on the appliance verify the correct tightness of all the gas
connections.
Tighten securely all the connections, ensuring the connection incorporating the seal
is at least 15 Nm and does not exceed 20 Nm.
If required by the type of gas, use a pressure regulator that complies with current
regulations.
At the end of the installation, check for any leaks with a soapy solution, never with a
flame.