Conversion Instructions

Conversion Kit
6
2 Gas connection
Check that the main gas supply line to the
range is shut off and that the power supply
cord is disconnected.
3 Adaptation to different types of gas
To adapt the regulator to the type of gas used,
the following must be done:
1. Unscrew the cover of the pressure
regulator.
2. Unscrew the spring retainer from the cover.
3. Screw the spring retainer back on
according to the type of gas used (see the
following illustrations).
Natural Gas: Set pressure to 5” W.C.P.
Incoming line pressure of 6” - 10 1/2”
W.C.P maximum.
LP Gas: Set pressure to 10” W.C.P.
Incoming line pressure 11”- 13” W.C.P.
maximum.