Operating Instructions and Installation Instructions

4. INSTALLATION
12
IT
EN
4.1 Dimensions of the appliance
The overall dimensions are illustrated in FIG. 5 - PG. 21 with the cavity diagrams.
The overall dimensions include the trivet (pan support), control knobs, handles and gas connection.
4.2 Fitting cavity
WARNING
WARNING
The appliance must fitted at an appropriate and safe distance from flammable
materials.
WARNING
WARNING
For the CU..., FO... and VN555 models, the cavity that the appliance is built into
must be completely sealed off. It is important that the inside panels of the cavity are
completely sealed and do not communicate with adjoining cavities or the outside.
The openings in the cavity that allow access to the gas and electric connections
should be sealed with rubber or foam.
The gas connection (1/4 BSPT female) is located at the rear for models CU..., FO... and for model VN555,
whereas it is on the bottom for models PI... and MO...
The electric connection is located at the rear for models CU..., FO... and for model VN555, whereas it is on
the bottom for models PI... and MO... (consult chapter 4.4 Electric connection to see whether the appliance
needs this connection).
Minimum allowable distances from walls (FIG. 4 - PG. 20)
200 mm From the external edge of the burner head nearest to a side and / or back wall.
600 mm Between the top part of the burners and cabinets and / or shelves fitted above the hotplate.
100 mm From the sides of the appliance and vertical walls.
170 mm From the top side to the cabinets and / or shelves fitted above the appliance.
Dimensions of fitting cavity
Cut out a hole in the cabinet as illustrated in FIG. 5 - PG. 21 size will depend on appliance model.
The cabinet must be appropriately constructed and aligned horizontally with the worktop and with the unit.
The cabinet aperture must be perfectly squared and aligned. If there are apertures for cabinet ventilation,
prevent flammable materials from entering these.
4.3 Gas connection
WARNING
WARNING
This appliance shall be installed only by authorised persons and in accordance with
the manufacturer’s installation instructions, local gas fitting regulations, municipal
building codes, electrical wiring regulations, AS 5601-2004 - Gas Installations and any
other statutory regulations.
WARNING
WARNING
This appliance is not connected to a flue terminal which discharges the product of
combustion to the outside. Any enclosed space in which the appliance is installed
must therefore be provided with permanent ventilation in accordance with relevant
federal and state regulations in force, and the requirements of gas installations with
particular attention being paid to the matter of room ventilation.