To connect the appliance use a 1.5 mm
2
double red and black wire and wire to the terminal junction box
located at the rear of the appliance with the wording “+12 V
“. The red terminal is the positive pole and
the black terminal is the negative pole.
High voltage 230-240 V~
This chapter refers only to the models listed in the table below.
Model Nominal voltage Nominal power
CU401PE - CU402PE - CU403PE
230-240V~ 800 W
In these models there is an electric plate in the hotplate.
WARNING
WARNING
When connecting direct to the mains supply, it is necessary to install a circuit
breaker which allows for disconnecting and isolating the appliance from the mains
in the event of overvoltage III conforming to installation regulations.
The supply cord must be positioned in such a way that it never reaches a temperature
of 75 °C above ambient in any point.
The plug must be easy to access after installation.
Always disconnect electrical power before working on or servicing the appliance.
For connecting to the mains power supply use a socket.
If the supply cord (H05RR-F 3x0,75mm
2
) is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
4.5 Fixture
CAUTION
CAUTION
This appliance is to be fixed and secured to the cabinet as described in FIG. 6 – PG.
26.
4.6 Testing (before leaving)
Ignite all burners both individually and concurrently to ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and observe stability of the flame for each burner individually and
concurrently. Ensure correct operation of the flame failure protection.
Depending on the type of gas used, the appearance of the flame is as follows:
Propane: flame with blue centre and well-defined contour.
Butane: flame with light yellow tips when igniting the burner, gradually intensifying as the burner heats.
CAUTION
CAUTION
In case the appliance fails to operate correctly after all checks have been carried
out, shut off the gas supply at the main gas tap and refer to the authorized service
provider in your area.
When satisfied with the appliance, please instruct the user on the correct method of operation.