- Standard Microsystems Single-Chip Ethernet Controller Specification Sheet

Single-Chip Ethernet Controller with HP Auto-MDIX Support and PCI Interface
Datasheet
Revision 1.22 (09-25-08) 78 SMSC LAN9420/LAN9420i
DATASHEET
D3
HOT
to D0
U
(T8): This transition occurs when PCInRST is asserted while in the D3
HOT
state
(PCInRST=1 to 0, PM_STATE=11b, VAUXDET=X, PWRGOOD=1). Refer to Section 3.7.5,
"Resets," on page 79 to for more information on this reset.
D3
HOT
to G3 (T12): This transition occurs when all power supplies are turned off (PCInRST=X,
PM_STATE=XXb, VAUXDET=1 to 0, PWRGOOD=1 to 0). For example, total power failure.
3.7.4.5 The D3
COLD
State
LAN9420/LAN9420i’s behavior in this state is dependant on the status of VAUXDET. When
VAUXDET=0, LAN9420/LAN9420i is powered from the system’s +3.3V supply; wake from D3
COLD
is
disabled and the PCI +3.3V power supply is off. Since VAUXDET=0, the device is powered from the
system’s +3.3V power supply and LAN9420/LAN9420i loses all power and context (to
LAN9420/LAN9420i, this appears identical to the G3 state).
When VAUXDET=1, LAN9420/LAN9420i is powered from the auxiliary power supply and the auxiliary
3.3Vaux supply remains operational. The device is isolated from the PCI bus and ignores all PCI
accesses, as well as PCInRST. If the PME Enable (PME_EN) bit in the PCI Power Management
Control and Status Register (PCI_PMCSR) is set, it is assumed that the device is configured to detect
a wake event from D3
COLD
. In this state the PCI 3.3Vaux power is on, but normal Ethernet receive
and transmit operation is disabled. In D3
COLD
power is reduced by disabling the internal PLL and
derivative clocks.
3.7.4.5.1 POWER MANAGEMENT EVENTS IN D3
COLD
If configured to do so, the device is capable of detecting MAC (WOL, Magic Packet) and PHY (link
status change) wake events and is capable of asserting nPME as a result of detection. In order to
generate nPME in the D3
COLD
state, LAN9420/LAN9420i must be powered from the 3.3Vaux power
supply.
3.7.4.5.2 EXITING THE D3
COLD
STATE
The device will exit the D3
COLD
state under the following conditions. State transitions are illustrated in
Figure 3.28 on page 75.
D3
COLD
to D0
U
(T9): This transition occurs when the +3.3V power supply is turned on. If VAUXDET
= 1, this means that the 3.3Vaux supply was active and PCI power is now turned on (PCInRST=1
to 0, PM_STATE=11b, VAUXDET=1, PWRGOOD=0 to 1). In this case the entire device is reset,
with the exception of the PCI PME context, which is preserved. The internal PHY is reset and is
configured for all capable operation with auto negotiation enabled.
If VAUXDET = 0, the device is seeing power for the first time and the internal power-on reset (POR)
is asserted (PCInRST=1 to 0, PM_STATE=X, VAUXDET=0, PWRGOOD=0 to 1). All logic and
registers are reset and the internal PHY is configured for all capable operation with auto negotiation
enabled.
D3
COLD
to G3 (T12): This transition occurs when all power supplies are turned off (PCInRST=X,
PM_STATE=XXb, VAUXDET=1 to 0, PWRGOOD=1 to 0). For example, total power failure.