Scope and Multimeter Operations Using the Scope Module Remotely
NOTE:
i If the Scope Module:
Is undocked from the Diagnostic Tool when it is on, or
Is exposed to a electro static discharge (ESD) while it is being used remotely
the following will occur:
• Communication between the Diagnostic Tool and the Scope Module will be terminated.
• All current data and settings will be lost.
• An error message (e.g. Meter/Scope Not Found) will display to indicate that
Scope Module communication has terminated.
When communication is reestablished (after a communication loss), the Scope Multimeter
application is restarted and the Scope Multimeter main menu page is displayed.
NOTE:
i When the Scope Module is connected to it’s docking station or is connected to the Diagnostic Tool
with a USB cable remotely, the Scope Module USB connection status indicator (lower right of
screen) is displayed. When the Scope Module is removed from the docking station, and is not
connected by a USB cable the status indicator is not displayed.
z To setup the Scope Module for remote operation:
1. Depress the Scope Module release tab located on the top of the Diagnostic Tool (Figure 8-1).
Figure 8-1 Scope Module release tab
2. Slide the Scope Module off of the Diagnostic Tool.
3. Locate the USB jack on the bottom of the Scope Module (Figure 8-2).
Figure 8-2 Scope Module USB jack location
4. Connect the square end of the USB cable to the jack on the Scope Module.
5. Connect the rectangular end of the USB cable to either of the two ports on the Diagnostic Tool.
The Scope Module is now ready for remote use.