14
10
Service – Removing Remote Lock
Module
Follow these steps to remove the ECKO remote lock
receiver module:
1. Open door of tool storage unit.
2. Remove DC jack from remote lock module.
3. Disengage snap-t tabs on cover with at
head screwdriver.
4. Swing open cover from case carefully,
squeeze tab on wiring harness to disconnect
cover assembly from case.
5. Remove pin, rotate spring to reveal access
to cam screw
6. Disengage snap-t tabs on actuator link clamshell
and remove clamshell.
7. Disengage snap-t end of actuator link.
8. Remove cam screw. Cam and lock rod assembly
can now be removed.
9. Remove nut and washer from lock cylinder, lock
can be removed through front of door.
10. Drill out rivet using 1/8” drill bit. Reinstall in re-
verse order. When installing cam, make sure that at
on inner cam aligns with at on lock.