Admin and Installation Guide M700, M300 Firmware Update
Registering M5 repeaters
The maximum number of repeaters per base station is 3 (three). In a single-cell system, the base
station (the DECT sync source) will always be RPN00; the repeaters will be numbered RPN01, RPN02,
and RPN03. In a multicell system, you can look up the RPNs of base stations and repeaters on the
Multicell page of the web user interface.
There are two DECT sync modes, Manual and Local Automatical. Automatic sync mode is
recommended for repeaters registered directly at the base station or - in a multicell system - directly
at the primary or any secondary base station in the chain. When repeaters are daisy-chained to other
repeaters, manual sync mode must be used.
Automatical registration
When this method is used, the repeater will look for the best base station signal, and the base station
will automatically assign an RPN. This method is recommended for registering repeaters directly at
the base station.
1. Open the Repeaters page.
Fig. 1
2. Click on Add Repeater (Fig. 1).
3. Enter a name for the repeater, for example a consecutive number or its location. This name will
be listed in the Name/IPEI column on the Repeater page (Fig. 3); if you do not enter a name, the
IPEI will be listed instead.
Fig. 2
4. Select Local Automatical from the DECT sync mode drop-down menu.
5. Click on Save.
Fig. 3