Operation Manual

22
v1.04
Provisioning Guide M700, M300 Settings and Configuration
Repeater Settings
Repeater Settings
Setting Value(s) Description
repeater_rpn
idx=1-100
1, 2, 3 The setting is used when repeater_auto_config_
mode is set to manual. Together with the setting
repeater_sync_src_rpn, this allows to specify a
unique RPN value per repeater.
Default Value: 0
repeater_sync_src_rpn
idx=1-100
0, 1, 2, 3, 4, 5, etc. The setting is used when repeater_auto_config_
mode is set to manual.
Together with the setting repeater_rpn it is possible
to specify a unique RPN value for every repeater.
The maximum chain length is three repeaters in
a chain after the base station. All repeaters using
manual mode must be configured to use a unique
RPN.
By default, this setting uses the base station at
index 0 in network_sync _mac_chain as the DECT
synchronization source.
Value 1 uses the repeater with RPN 1 which is
connected to the base station in network_sync_mac_
chain index 0 as the DECT sync source.
Value 2 uses the repeater with RPN 2 which is
connected to the base station in network_sync_mac_
chain index 0 as the DECT sync source.
Value 3 uses the repeater with RPN 3 which is
connected to the Base station in network_sync_mac_
chain index 0 as DECT sync source.
Value 4 uses the base station at index 1 in network_
sync_mac_chain as the DECT sync source.
Value 5 uses the Repeater with RPN 1 which is
connected to the base station in network_sync_mac_
chain index 1 as the DECT sync source.
Default Value: 0
repeater_name
idx=1-100
Specifies the name of the Repeater.
Default Value: <empty>