Operation Manual

23
v1.04
Provisioning Guide M700, M300 Settings and Configuration
Repeater Settings
Setting Value(s) Description
repeater_auto_config_
mode idx=1-100
0 = Manual
1 = Local
2 = Chaining
If set to 0 (= manual), specify repeater_rpn and
repeater_sync_src_rpn.
If set to 1 (= local), the repeater will automatically
search for available base stations and locate the
base with the best signal. If that base station is
turned o, the repeater will move to the next best
base station.
If set to 2 (= chaining), all base stations and all
repeaters will send RSSI reports to the primary base
station. These reports are used by the primary base
station to create a DECT synchronization tree with all
base stations and all repeaters that have this setting
configured.
Default Value: 0
repeater_legacy_
support
o / on This setting controls whether legacy repeaters are
supported or not.
Default Value: o
repeater_data_
configured idx=1-100
o / on When this setting is set to on, the specific repeater
is actively configured; when set to o, this account is
not in use.
Default Value: o
repeater_dect_ipui
idx=1-100
Repeater International Portable User Identity. This is
normally not configured via provisioning.
Default Value: <empty>