Use and Care Manual

Inlet Pipe Diameter must be larger than 9.5 mm [3/8 inch].
Drain Pipe Diameter must be larger than 15.8mm [5/8 inch] and drop 3 cm
per meter [3/8 inches per foot].
DRAIN PIPE INSTALLATION NOTE: To prevent drain water from flowing back into
the ice machine and storage bin the following rules must also be complied with:
1.) No point in the drain pipe shall be higher than the drain outlet from the ice
machine.
2.) No point in the middle of the drain pipe shall be lower than any point beyond it
such that a trap is created.
It is recommended that drains have a joint or other suitable means to allow
disconnection from the ice machine when servicing is required.
All water supply and drain plumbing must comply with local, state and
national codes.
It is recommended that water supply and drain lines be insulated to prevent
condensation.
2.4 Power Supply Requirements
The following electrical supply requirements must be complied with or the system
may not operate correctly or damage may occur:
All wiring must conform to local, state and national codes.
The voltage, frequency and capacity of power supply provided must be
consistent with that marked on the machine nameplate.
The maximum allowable voltage variation is 10% of the rated voltage on the
ice machine model/serial number plate at start-up (when the electrical load
is highest).
The earth terminal of the power supply, socket or plug must be connected
to external grounding.
Ice Machine Outlet
To Drain