PROBLEM POSSIBLE CAUSE SOLUTION
Control shut down Jammed auger Clear jammed auger. Use caution
Poor electrical connections Clean/replace connectors
Use dielectric grease
Electrical short Check all connections
Check for bare wires
Control failure Replace Control Module
OL/OH Jammed auger Switch off, then on (for Auto-Reverse)
If it continues. Turn off. Clear jam
Bad Connection Check connections/Dielectric grease
Clean/replace connectors
Bad motor Check with Test Kit
Bad transmission Replace
Bad Control Module Check with Test Kit
EO Motor is not getting power Turn Off. Check all connections
Break in wiring harness Repair/Replace
E1 Short in motor circuit Turn off. Do not use until short is corrected
Check/Replace connections
Check for bad motor
LB Low Battery Turn off. Charge battery
Poor connection Turn Off. Check all connections
No Display. Nothing lights up Bad Control or Bad Control Module Check with Test Kit
Bad Pendant Cord Replace