Datasheet
SONARANGE UPR-A 04.17 e
This Information corresponds to the current state of knowledge. SNT reserves the right to make technical changes. Do not use these products in any application
where failure of the product could result in personal injury. Liability for consequential damage resulting from the use of SNT products is excluded.
SNT Sensortechnik AG, Hammerstrasse 6, CH-8180 Bülach, Switzerland, Phone +41 44 817 29 22, Fax +41 44 817 10 83, info@sntag.ch 1/6
www.sntag.ch
Ultrasonic distance and proximity sensors
UPR-A Series
Technical data
UPR-A 1500 TOR 24 C(W)AI
UPR-A 1500 TVPA 24 C(W)
Detection range
mm
120...1500
Blind range (no reasonable analogue signal)
mm
0...120
Hysteresis of binary output, axial
mm
-
4
Resolution
mm
~0.5
Linearity
%FS
<1
-
Over all accuracy in whole temperature range
*1)
%FS
<2
Operating frequency
kHz
~180
Status indicator
-
LED yellow/red
Binary output, short circuit proof, max. 0.1A
-
-
PNP NO/NC
Switching speed max.
Hz
-
~5
Time to readiness when power on
s
1.3
Speed of analogue output
Hz
~30
-
Analogue output: R
L
min. 10k with V output
R
L
max. 400 with mA output
V
mA
0...10V
4...20mA
-
-
Power supply voltage (reversal polarity protection)
VDC
11...30
Ripple of supply voltage
%
10
Mean consumption
mA
~45…65
~45
Temperature range
*2)
°C
0...+60
Pressure range
mbar
abs
900...1100
Mass
g
~65
Protection class
-
IP67
Housing material
-
nickel plated brass
Electrical connection
-
M12 connector 4-pin
Option: for ATEX zones 2+22
-
Ex tc IIIC T60°C Dc 0°C ≤ Ta ≤ +60°C
Ex nA IIC T6 Gc 0°C ≤ Ta ≤ +60°C
Option: stainless steel housing (incl. connector)
-
1.4571 (V4A)
*1)
The accuracy can be improved beyond by teaching the sensor only after it has reached its thermally stable state (e.g. after 30 minutes).
*2)
Operation <0°C is partially possible when the sensor membrane is kept free from icing by the self-heating in continuous operation or by external heating.
• Measuring distances from 120mm to 1500mm
• Analogue or binary output
• Teach-In
• Configurable beam size
• To be configured as scanner or retroreflective barrier
• Wide power supply voltage range 11…30VDC
• Very fast analogue output
• Watertight, IP 67, oil resistant, robust
• Measurement independent of material, surface,
colour and size of target
• Work under dust, dirt, fog, light
• Detect transparent and shiny objects
• Option: ATEX 2/22
• Option: stainless steel housing, 1.4571 (V4A)
• Option: chemically resistant housing
• Option: Synchronization and suppression mode
• Swiss made