Specifications_1
Review Door Opening Record
Each record is displayed in 2 pages, the first page shows password type used (PASS-1 means door opened by user
password, PASS-2 means administration password used ), the second page displays the opening date and time. Maxi-
mum 45 records can be stored, press 8 for previous record, press 0 for next.
Password Resetting
In the standby state, press the green setting button to enter the password setting state (located on the inner left side of the
door when its opened). When the screen displays shows "--------", enter 1-8 digits password, press "#" to confirm. If the
screen displays "Into", it indicates that the password is successfully set, then system enters the standby state.
Administration Password Resetting
Press the "#" key to wake up the panel, press the "0" key twice, and then press the green setting key to enter
the administration password resetting state. The screen displays "------", enter 1-8 digits password, press "#"
to confirm. If "Into" is displayed on the screen, the administration password is successfully set, and then
system enters the standby state.
System Date Resetting
(1)In the standby state, press "*" to enter system date resetting. The corresponding parameter will blink.
(2)Enter the corresponding number to adjust the date and time, and return to the standby state after the adjustment.
(3) During the setting, press the "*" key to go back one space and re-enter.
(4)During the setting state, if no key is pressed within 10S, the state will be exited (the modified value is invalid). System
will return to standby.
Vibration Alarm Function
(1)In the standby state press "0", the screen displays “Bell on” and enters the alarm state.
(2)In the alarm status, the safe will alarm if encounters vibration(violent hit), and the screen displays an alarm sign.
(3) At this time, enter the correct password, the screen displays "OPEN" and opens the door to stop the alarm.
(4)When the system is in alarm, perform any correct opening action will deactivate the alarm
Power and voltage indication
(1)Power supply: use four 1.5V batteries. When the voltage is full, the solid battery symbol is displayed. When the voltage is
undervoltage, it displays a hollow battery symbol. The screen displays “LO-BATT” .It reminds user to replace the battery.
(2)Undervoltage reminder: 4.5±0.3V quiescent current: <20uA Maximum current: <350mA
1. place the safe at the installation place,.Mark the drilling spots on the wall from
the inside pre-drilled holes, then remove safe and drill two holes.
2.Put the expansion bolts into the drilled holes, take the expansion bolt out of the
sleeves , then place the safe and align the pre-drilled holes with drilled holes, and
insert the expansion bolts into its sleeves from inside of the safe.
(This safe has four mounting holes, two are on the back of the safe and the others
are on the bottom of the safe)
How to install foot mat?
1.Remove the stickers of the four
foot mats
2.install the four foot mats on the
bottom of the safe
How to mount the safe?


