Instructions
3
HOW TO PERFORM A CABLE TEST
Press the red power buon to turn the CableMaster 800/850 on
• Connect a network cable to the CableMaster 800/850 then connect a Network/Telephone
tesng remote to the opposite end of the cable. From the home screen, press the enter
buon or cable test so key to display the cable test menu. The CableMaster 800/850 will
automacally perform a test upon entering the cable test menu.
• To test coax cable, connect a coax cable to the CableMaster 800/850, then press the coax so
key .
• To test telephone cable, connect the CableMaster 800/850 to a telephone cable using RJ12 patch
cable, press the coax so key then the telephone so key.
• If a remote is NOT being used (one ended test), the CableMaster 800/850 will test the length of
each pair, opens, shorts, or split pairs. Performing a one ended test will not verify connecvity on
the opposite end of the cable.
• To calibrate the VoP, connect a known length of cable to the CableMaster 800/850 and press the
up/down/le/right buons to increase or decrease the VoP. Press the le and right buons to
select and change the VoP one digit at a me.
• While adjusng the VoP, press the test buon unl the desired length of the cable is displayed.
• To save the calibrated VoP, go to the Setup 6 T3 Innovaon 33 and press the Save so
key (note: your adjusted VoP will be displayed next to the RJ45 or Coax icon). See page 3 for
Setup instrucons.
• Press the green test buon tests or the loop mode so key to perform addional tests
.
• To save a cable test, press the save so key .
• Use the arrow buons and the enter buon to name the cable test le.
• Press the Save so key again to save the test le .
HOW TO PERFORM A PORT DISCOVERY
TEST NETWORK/POE TEST
• Connect the CableMaster 800/850 to a switch or acve network jack.
• From the home screen, use the right arrow buon to select the Network/PoE icon and press
the enter buon or press the Network/PoE so key .
• The CableMaster 800/850 will automacally detect and display link capability, connecon speed,
PoE mode, and PoE Min/Max voltages.
• To perform a Network Test only, press the PoE o so key .
• To save the PoE data, press the Save so key .
• Use the arrow buons and the enter buon to name the PoE le.
• Press the Save so key to save the PoE le .