Third Party Verification Claim
NON-GLP STUDY REPORT      Date: June 2016 
Sponsor:  Sprinkler Magician 
Study:  Direct Spray 16 
Trial:  AEDSAE 
Sponsor Code:  N/A 
Test Method:  311 
MATERIALS AND METHODS: 
The  following  is  the  Snell  Scientifics  Standardized  Testing  Method  for  evaluating  the  efficacy  of 
pesticides when applied as direct spray applications against various arthropod species.  Further details 
related to this specific study are described following the test method summary. Select action items and 
illustrations  have  been  removed from  this  standardized  test  method  in  an  effort  to  make  the  report 
more precise and accurate to the study conducted. Any details removed from this test method were 
deemed irrelevant to the study conducted in this report. 
311.1    Materials: 
Test Arena Information: 
311.1.1  Treatment Arenas:  1.75” CPVC Mesh Cartridge (BioQuip 7250NSW mesh). The Test Arenas 
were used to contain the test systems during the test substance applications. 
311.1.2  Post-Treatment Arenas:  20oz SOLO cup with lid.  The Post-Treatment arenas were used to 
contain the test systems in a clean environment after exposure to the test substance(s). 
311.1.3  Food/Moisture:  10% sucrose soaked cotton swabs. 
Test Equipment:   
311.1.4  Volumetric  Measuring  Equipment:    Graduated  cylinders  and/or  beakers  were  used  as 
needed in preparing and/or measuring the flow rates of the test substance(s). 
311.1.5  Digital  Balance(s):    Balances  were  used  as  needed  in  preparing  and/or  weighing  the  test 
substance canisters before and after applications. 
311.1.6  CO
2 
and  Regulator:    A  standard  20  pound  CO
2 
cylinder  with  regulator  was  used  to 
anesthetize the test systems and sort them  into the test arenas  (prior to  exposure to  the 
test substances).  The test systems were allowed to adequately recover from anesthetizing 
before being exposed to the test substance(s), and they were not anesthetized at any point 
following  exposure  to  the  test  substance(s).    Any  additional  transfers  required  after 
exposure  to  the  test  substances  was  conducted  using  methods  that  did  not  involve 
anesthetizing.  
311.1.7  Intermediate Sorting/Transfer Containers:  Additional sorting and transfer containers were 
used to aid in moving the test systems from the primary rearing/collection containers and 
into the treatment and/or post-treatment arenas. 
311.1.8  Metronome/Timing Equipment: A metronome and/or other timing equipment were used as 
needed to assist in the timing when conducting the applications and/or when collecting the 
observations. 
Application Equipment: 
311.1.9  Application Equipment:  Snell Sci. Trigger Sprayer. 