P650 / P701 / P730 / P801
Power Optimizer Model
(Typical Module Compatibility)
P650
(for up to
2 x 60-cell PV
modules)
P701
(for up to
2 x 60/120-cell PV
modules)
P730
(for up to
2 x 72-cell PV
modules)
P801
(for up to
2 x 72/144 cell PV
modules)
INPUT
Rated Input DC Power
(1)
650
700*
730**
800
W
Connection Method
Single input for series connected modules
Absolute Maximum Input Voltage (Voc at lowest temperature)
125
Vdc
MPPT Operating Range
12.5- 105
Vdc
Maximum Short Circuit Current per Input (Isc)
11
11.75
11**
11.75
Adc
Maximum Efficiency
99.5
%
Weighted Efficiency
98.6
%
Overvoltage Category
II
OUTPUT DURING OPERATION
(
POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER
)
Maximum Output Current
15
Adc
Maximum Output Voltage
80
Vdc
OUTPUT DURING STANDBY
(
POWER OPTIMIZERDISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
)
Safety Output Voltage per Power Optimizer
1 ± 0.1
Vdc
STANDARD COMPLIANCE
EMC
FCC Part 15, IEC 61000-6-2, and IEC 61000-6-3 - Class B, EN 55011 - Class A
Safety
IEC62109-1 (class II safety)
RoHS
Yes
Fire Safety
VDE-AR-E2100-712:2013-05
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters
Three phase inverters SE16K & larger
(2)
Maximum Allowed System Voltage
1000
Vdc
Dimensions (W x L x H)
129 x 153 x 49.5 / 5.1 x 6 x 1.9
mm / in
Weight
933 / 2.1
gr / lb
Input Connector
MC4
(3)
Input Wire Length
0.16 / 0.52 , 0.9 / 2.95
(4)
m / ft
Output Connector
MC4
Output
Wire Length
Portrait orientation:1.2 / 3.9
m / ft
Landscape orientation: 1.8 / 5.9
Landscape orientation: 2.2 / 7.2
Operating Temperature Range
(5)
-40 to +85 / -40 to +185
˚C / ˚F
Protection Rating
IP68 / NEMA6P
Relative Humidity
0 - 100
%
* For P701 models manufactured after work week 06/2020, the rated DC input is 740W
** For P730 with manufactured date greater than working week 06 of 2020 the rated DC input is 760W and maximum Isc per Input is 11.75A
The manufacture code is indicated in the Power Optimizer's serial number. Example: S/N SJ0620A-xxxxxxxx (working week 06 in 2020)
(1) Rated power of the module at STC will not exceed the Power Optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed
(2) For compliance with EN 55011 class A (where required), installation shall be done with inverter 20kVA or larger, and comply with the requirements in the EMC section of the installation manual
(3) For other connector types please contact SolarEdge
(4) Longer inputs wire lengths are available for use with split junction box modules. (For 0.9m/2.95ft order P730-xxxLxxx)
(5) For ambient temperature above +70˚C/ +158˚F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details
PV System Design Using a
SolarEdge Inverter
(6)(7)(8)
230/400V Grid
SE25K*, SE33.3K*
230/400V Grid
SE27.6K*
230/400V Grid
SE30K*
277/480V Grid
SE33.3K*, SE40K*
Compatible Power Optimizers
P650, P701, P730, P801
P650, P701, P730, P801 P650, P701, P730, P801 P650, P701, P730, P801
Minimum String
Length
Power Optimizers
14 14 15 14
PV Modules
27 27 29 27
Maximum String
Length
Power Optimizers
30 30 30 30
PV Modules 60 60 60 60
Maximum Continuous Power per String
11250 11625 12750 12750
W
Maximum Allowed Connected Power per String
(9)
(Permitted only when the difference in connected power between
strings is 2,000W or less)
13500 13875 15000 15000
W
Parallel Strings of Different Lengths or Orientations
Yes
* The same rules apply for Synergy units of equivalent power ratings, that are part of the modular Synergy Technology inverter
(6) P650/P701/P730/P801 can be mixed in one string only with P650/P701/P730/P801
(7) For each string, a Power Optimizer may be connected to a single PV module if 1) each Power Optimizer is connected to a single PV module or 2) it is the only Power Optimizer connected to a single PV module in the string
(8) For SE25K and above, the minimum STC DC connected power should be 11KW
(9) To connect more STC power per string, design your project using SolarEdge Designer