Application Note: Inter-Compatibility
Version 10.0, December 2021 1
SolarEdge Power Optimizers Inter-Compatibility
Version History
Version 10 (Dec 2021) Updates for commercial Power Optimizer compatibility, P850, P860, P950, P960, P1100.
Version 9 (Nov 2021) – added S440, S500 and S500B.
Version 8 (Aug 2021) – marked P400 and P401 as being inter-compatible.
Version 7 (May 2021) – added P375, P601, P605, P960, P1100. Re-added P300, P600, P700.
Version 6 (Sept. 2020) – marked P950 as compatible with P850 and P800p.
Version 5 (June 2020) - added P320, P340, P370T, P395, P400, OP400-EV,OP-480, P401, P485, P700, P801, P850, P860, P950 OP300-LV , OP350-LV, OP350-MV, OP600-96.
Deleted P300, P600, P700.
Added remark about M2640 and M1600.
Merged Europe and APAC and NAM to a single document.
This technical note specifies inter-compatibility between various models of the S-Series and P-Series SolarEdge power optimizers, as well as the inter-compatibility of the P-Series power
optimizers with previous series of power optimizers (PBxxx and OPxxx).
The term “inter-compatibility” refers exclusively to the installation of power optimizers in the same PV string.
When replacing a power optimizer, the replacement power optimizer does not need to be identical to the replaced power optimizer, but it must be compatible with the other power
optimizers in the string.
NOTE
Installing different series and models of power optimizers in the same installation is allowed as long as they are installed in separate PV strings. However, power optimizers that are
inter-compatible may be installed in the same PV string.
NOTE
When replacing a power optimizer always verify with the SolarEdge Designer that the power, current and voltage specifications of the PV module are compatible with the
replacement power optimizer specifications. Ensure that the module Voc (at minimum ambient temperature) does not exceed the replacement power optimizer’s maximum input
voltage. Use the SolarEdge Designer to quickly validate electrical compatibility.
Refer to the power optimizer datasheet for details.