Cut Sheet

INVERTER SPECIFICATIONS:
EV Charging Single Phase Inverter
for North America
SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE11400H-US
SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE11400H-US
OUTPUT
Rated AC Power Output 3800 5000 6000 7600 11400 VA
Max. AC Power Output 3800 5000 6000 7600 11400 VA
AC Output Voltage Min.-Nom.-Max. 211 - 240 - 264 Vac
AC Frequency (Nominal) 59.3 - 60 - 60.5
(1)
Hz
Maximum Continuous Output Current 16 21 25 32 47.5 A
GFDI Threshold 1 A
Utility Monitoring, Islanding Protection, Country
C o n g u r a b l e T h r e s h o l d s
Yes
INPUT
Maximum DC Power 5900 7750 9300 11800 17650 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage 480 Vdc
Nominal DC Input Voltage 380 400 Vdc
Maximum Input Current 10.5 13.5 16.5 20 30.5 Adc
Max. Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600k
Sensitivity
Maximum Inverter Efficiency 99.2 %
CEC Weighted Efficiency 99 %
Nighttime Power Consumption < 2.5 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)
Smart Energy Management Export Limitation and Excess Solar Charging
(2)
Revenue Grade Data, ANSI C12.20 Optional
(3)
Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi access point for local connection
Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
STANDARD COMPLIANCE
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / AWG Range 1” maximum / 14-6 AWG
1” maximum /
14-4 AWG
DC Input Conduit Size / # of Strings / AWG Range 1” maximum / 1-2 strings / 14-6 AWG
1” maximum /
1-3 strings / 14-6
AWG
Dimensions with Connection Unit with Safety Switch
(HxWxD)
17.7 x 14.6 x 6.8 / 450 x 370 x 174
21.3 x 14.6 x 7.3 /
540 x 370 x 185
in / mm
Weight with Connection Unit with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg
Noise < 25 <50 dBA
Cooling Natural Convection
Operating Temperature Range -40 to +140 / -40 to +60
(4)
˚F / ˚C
Protection Rating NEMA 4X (Inverter with Connection Unit with Safety Switch)
(1) For other regional settings please contact SolarEdge support
(2) Import/Export meter is required for Export Limitation and for controlled Excess Solar charging
(3) Revenue grade meter P/N: SExxxxH-US000BNW4
(4) Full power up to at least 50°C/122°F . For power de-rating information refer to: https://www.solaredge.com/sites/default/les/se-temperature-derating-note-na.pdf