Install Manual

To verify meter connection:
1. PresstheEnterbuttonortheLCDexternalbuttonuntiltheCommunicationstatusscreenis
displayedasshownbelow.Thisscreenshowsthenumberofexternaldevicesthatcommunicateon
eachport,thedevicetype,andtheprotocoltowhicheachportwasconfigured.
2.
VerifythatthesettingoftherelevantRS485portiscorrectandthattheportiscommunicatingwith
themeter.
Forexample,ifthemeterisconnectedtotheRS485-1port,theCommunicationstatusscreenshould
displaythefollowing:
w w w w w w w D e v P r o t # #
R S 4 8 5 - 1 < M T R > < W N > < 1 >
R S 4 8 5 - 2 < - - - > < - - > < - - >
Z i g B e e < - - - > < - - > < - - >
Dev:thetypeofdeviceconfiguredtothisport.MTR indicatesameter.
Prot:thecommunicationprotocol
## = 1:Indicatesthattheconnectiontothemeterissuccessful.
3.
PresstheEnterbuttonortheLCDexternalbuttonuntilreachingthemeterstatusscreenshowing
thetotalenergy[Wh].Ifthereismorethanonemeter/function,thereisastatusscreenforeachone.
ThefollowingisanexampleofanExportmeter:
E x p o r t M e t e r
S t a t u s : < O K / E r r o r # >
P o w e r [ W ] : x x x x x . x
E n e r g y [ W h ] : X X X X X . X
Status:DisplaysOKifthemeteriscommunicatingwiththeinverter.
<Error message>:Ifaninternalmetererroroccurs,itwillbedisplayedhere.RefertoTroubleshooting
Meter Connectiononthefacingpage.
Total [Wh]:Displaystheaccumulatedlifetimeenergyofthemeter.
IftheSolarEdgedeviceisconnectedtotheSolarEdgeserverthisvaluewillalsobedisplayedinthe
monitoringportal.
To display the meter serial number:
1.
EnterSetupmodeandselectInformation.Thefollowingscreenisdisplayed:
V e r s i o n s
E r r o r L o g
W a r n i n g l o g
H a r d w a r e I D s
2.
SelectHardware IDs.ThefollowingisdisplayedshowingtheIDoftheinverterandanymeter
connectedtoit:
I D 5 0 0 0 F F F F 4 E
R G M : 1 2 3 4 5 6 7 8
SolarEdge SolarEdge Electricity Meter Installation Guide MAN-01-00270-1.0
14
Chapter 3: SolarEdge Device Configuration