## :Thenumberofcommunicatingmeters.Fordualmetersitshoulddisplay2.Ifnot,referto
Troubleshootingbelow.
2.
PresstheEnterbuttonortheLCDexternalbuttonuntilreachingtheMeterstatusscreenshowing
thetotalenergy[Wh].Thereisastatusscreenforeachmeterfunction.Forexample,foran
export+importmeterandaproductionmeter,therewillbethreestatusscreens:forexport,import
andproduction.Thefollowingisanexampleofanexportmeter:
E x p o r t M e t e r
S t a t u s : < O K >
< E r r o r M e s s a g e >
T o t a l [ W h ] : X X X X X X X
Status:DisplaysOKifthemeteriscommunicatingwiththecommunicationboard.
<Error message>:Ifaninternalmetererroroccurs,itwillbedisplayedhere.RefertoTroubleshooting
Meter Connectiononpage15.
Total [Wh]:TheamountofWattsperhourofthedesignatedmeter.
IftheSolarEdgedeviceisconnectedtotheSolarEdgeserverthisvaluewillalsobedisplayedinthe
monitoringportal.
Troubleshooting Dual-meter Connection
Communication Status Screen Troubleshooting
WhentwometersareconnectedonthesameRS485bus,thefollowingshouldappearinthe
Communicationstatusscreen:
w w w w w w w w D e v P r o t # #
R S 4 8 5 - 1 < M L T > < 0 2 > < 0 2 >
R S 4 8 5 - 2 < - - - > < - - > < - - >
Z i g B e e < - - - > < - - > < - - >
Device Type or Protocol are configured incorrectly
IfMLT(Multi)isnotdisplayedasthedevicetype(DEV),or2isnotdisplayedasthenumberofmeters
underProt(protocol),configurethemetersasfollows:
1. SelectCommunication è RS485-x Conf è Device Type è Multi Devices.SelectDevice 1orDevice
2.
2. SelectCommunication è RS485-x Conf è Protocol èWattNode.
3. SelectRevenue Meter è Meter Func. è Production,Consumption,Export,Import,or
Export+Import.
4. CheckthattheDeviceIDunderCommunication è RS485-x Conf è Device IDissetto1or2.
Number of devices is lower than configured or not displayed
If<-->or<01>isdisplayedunderthe##columnintheCommunicationstatusscreenshownabove,at
leastoneofthemetersisnotcommunicatingwiththeinverter.Checkthefollowing:
l Themeterconfigurationisasdescribedabove.
l Therearenolooseconnectionsattheinverterconnectorsandatthemeters,specificallytheRS485
wiring.
Meter Status Screen Troubleshooting
RefertoMeter Status Screen Troubleshooting onpage15.