Installation Manual
RS485 Surge Protection Kit Installation Guide - MAN-01-00338-1.1
1
RS485 Surge Protection Kit Installation Guide
This document describes how to install the RS485 Surge Protection Kit in a SolarEdge inverter.
Kit Contents
Surge protection board
Figure 1: Surge Protection Board
Installation Procedure
1 Turn the inverter ON/OFF switch to OFF. The inverter display should indicate that the string voltage is in the
safety voltage range (< 50V).
2 Disconnect the AC to the inverter by turning OFF the circuit breakers on the distribution panel.
3 Do one of the following:
For a new RS485 connection installation, disconnect the 9-pin connector from the surge protection board, and
connect the RS485 wires to the G, A, and B terminals of the 9-pin connector, as shown in Figure 2.
Figure 2: 9-Pin Connector for a New Inverter Installation
If RS485 connection is already installed in the inverter, disconnect the 9-pin connector from the inverter’s
communication board (leaving the RS485 wires intact), as shown in Figure 3.
Figure 3: Disconnecting the 9-Pin Connector from an Existing Inverter
4 Remove the inverter grounding screw, as seen below in Figure 4. Position the ring terminal of the surge
protection board in its place, and replace and tighten the screw.
Disconnect
Disconnect