Install Manual

Table Of Contents
Indication
ON/ OFF/ P
switch
position
LED color
Comment
Red Green Blue
Power optimizers not
paired
ON (1)
OFF Blinking
o
S_OK: ON
o
No S_OK: OFF
S_OK: ON
communication
with the
monitoring
platform is
established.
Pairing Blinking Blinking Blinking
Wake-up/ Grid
Monitoring
OFF Blinking Blinking
System Producing OFF ON
o
S_OK: ON
o
No S_OK: OFF
Night mode
(no production)
OFF Flickering
o
S_OK: ON
o
No S_OK: OFF
Inverter is OFF
(Safe DC)
OFF (0)
OFF Blinking
o
S_OK: ON
o
No S_OK: OFF
Inverter is OFF
(DC not safe)
Blinking Blinking
o
S_OK: ON
o
No S_OK: OFF
Inverter
configuration
or reboot
ON / P ON ON ON
Inverter firmware
upgrade
ON / P Alternating Alternating Alternating
The upgrade
process can
take up to 5
minutes
Error Any ON
ON/ OFF/
Blinking/
Flickering
ON/ OFF /
Blinking
Refer to Errors
and
Troubleshooting
on page 54
ThefollowingtabledescribesprodcutionpercentageofACinformationbyLEDcolorandON/OFF/P
switchposition.
Indication
ON/
OFF/ P
switch
position
LED color
Comment
Red Green Blue
Percentage of AC Production:
> 0 - 33 %
ON (1)
OFF OFF OFF
This indicates
power production
as percentage of
rated peak AC
output power
Percentage of AC Production:
0 - 33 %
OFF ON OFF
Percentage of AC Production:
33 - 66 %
OFF OFF ON
Percentage of AC Production:
66 - 100 %
OFF ON ON
-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.0
24
Inverter Interfaces