Install Manual
Table Of Contents
- Disclaimers
- Revision History
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimisers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Activating, Commissioning and Configuring the System Using the Inverter SetApp
- Chapter 6: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Mechanical Specifications
- Appendix C: Replacing and Adding System Components
- Technical Specifications - Single Phase Inverters with HD-Wave Technology (No...
ForP(Q)diagramrefertohttps://www.solaredge.com/sites/default/files/application_
note_p_q_diagram_of_se_inverters_en_and_na.pdf.
NOTE
SolarEdge inverters with “Grid Support” functionality (as marked on the inverter certification label), are
compliant with UL 1741 Supplement A. The functionality is built into the inverter and no additional
external device is required.
Device Manager
FromtheCommissioningmenu,selectDevice ManagertoconfigurevarioussystemSmartEnergy
Managementdevices.
Formoreinformationrefertohttps://www.solaredge.com/products/device-control#/.
Maintenance
FromtheCommissioningmenu,selectMaintenancetoconfigurevarioussystem
settings,asdescribedbelow.
l Date and Time:Settheinternalreal-timeclock.Ifconnectedtothemonitoringplatform,thedate
andtimearesetautomaticallyandonlytimezoneshouldbeset.
l Reset Counters:Resetstheaccumulatedenergycountersthataresenttothemonitoringplatform
l Factory Reset:Performsageneralresettothedefaultdevicesettings.
l Firmware Upgrade:Performasoftwareupgrade.
l Load / Save Configuration:Enablessavingorloadingsystemparametersfromoneinverterto
another.
l Diagnostics:DisplaystheIsolationstatusandpoweroptimizerstatusscreens.Refer
tohttps://www.solaredge.com/sites/default/files/application_note_isolation_fault_
troubleshooting.pdf.
l Activate Standby Mode:Enables/disablesStandbyMode-forremotecommissioning.
l Grid Protection:Availableinspecificcountries.Enablesviewingandsettinggrid
protectionvalues.
l Board Replacement:Backsupandrestoresthesystemparameters,includingenergycounters;Used
duringboardreplacementaccordingtotheinstructionssuppliedwithreplacementkits.
Information
FromtheCommissioningmenu,selectInformationtoviewandsetvarioussystemsettings,asdescribed
below.
l CPU Version:Thecommunicationboardfirmwareversion
l DSP 1/2Version:Thedigitalboardfirmwareversion
NOTE
Please have these numbers ready when you contact SolarEdge Support.
l Serial Number-Theinverterserialnumberasappearsontheenclosuresticker
-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.0