Install Manual
Table Of Contents
- Disclaimers
- Revision History
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimisers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Activating, Commissioning and Configuring the System Using the Inverter SetApp
- Chapter 6: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Mechanical Specifications
- Appendix C: Replacing and Adding System Components
- Technical Specifications - Single Phase Inverters with HD-Wave Technology (No...
Chapter 6: Setting Up Communication
Theinvertersendsthefollowinginformationtothemonitoringplatform:
l PoweroptimizerinformationreceivedviatheDCpowerlines(thePVoutputcircuit)
l Inverterinformation
l Informationofanyotherconnecteddevices
Thischapterdescribessettingupcommunicationbetween:
l theinverterandthemonitoringplatformthroughtheInternet(wired/wireless),orthroughacellular
connection
l multipleinvertersforamaster/slaveconfiguration
Communicationsetupisnotrequiredforpowerharvesting,howeveritisneededforusingthe
monitoringplatform.
CAUTION!
When connecting the communication cables, make sure that the ON/OFF switch on the Safety Switch
is turned OFF, and the AC is turned OFF.
When configuring the communication parameters, make sure that the ON/OFF switch on the Safety
Switch is OFF, and the AC is turned ON.
ATTENTION!
Lors de la connexion des câbles de communication, assurez-vous que l'interrupteur MARCHE/ARRÊT
à la base de l'onduleur soit en position ARRÊT, et le CA est en position ARRÊT. Lors de la
configuration des paramètres de communication, assurez-vous que l'interrupteur MARCHE/ARRÊT
soit en position ARRÊT, et le CA est en position MARCHE.
Communication Options
Thefollowingtypesofcommunicationcanbeusedtotransferthemonitoredinformationfromthe
invertertothemonitoringplatform.
OnlycommunicationproductsofferedbySolarEdgearesupported.
Ethernet
EthernetisusedforaLANconnection.ForconnectioninstructionsrefertoCreatinganEthernet(LAN)
Connectiononpage47.
RS485
RS485isusedfortheconnectionofmultipleSolarEdgedevicesonthesamebusinamaster-slave
configuration.RS485canalsobeusedasaninterfacetoexternaldevices,suchasmetersandthirdparty
dataloggers.
ForconnectioninstructionsrefertoCreatinganRS485BusConnectiononpage50.
-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.0
44
Chapter 6: Setting Up Communication