Installation Manual

Chapter 6: Setting Up Communication
Theinvertersendsthefollowinginformationtothemonitoringplatform:
l PoweroptimizerinformationreceivedviatheDCpowerlines(thePVoutputcircuit)
l Inverterinformation
l Informationofanyotherconnecteddevices
Thischapterdescribessettingupcommunicationbetween:
l theinverterandthemonitoringplatformthroughtheInternet(wired/wireless),orthroughacellular
connection
l multipleinvertersforamaster/slaveconfiguration
Communicationsetupisnotrequiredforpowerharvesting,howeveritisneededforusingthe
monitoringplatform.
CAUTION!
When connecting the communication cables, make sure that the ON/OFF switch on the DC Safety
Unit is turned OFF, and the AC is turned OFF.
When configuring the communication parameters, make sure that the ON/OFF switch on the DC
Safety Unit is OFF, and the AC is turned ON.
ATTENTION!
Lors de la connexion des câbles de communication, assurez-vous que l'interrupteur MARCHE/ARRÊT
à la base de l'onduleur soit en position ARRÊT, et le CA est en position ARRÊT. Lors de la
configuration des paramètres de communication, assurez-vous que l'interrupteur MARCHE/ARRÊT
soit en position ARRÊT, et le CA est en position MARCHE.
Communication Options
Thefollowingtypesofcommunicationcanbeusedtotransferthemonitoredinformationfromthe
invertertothemonitoringplatform.
OnlycommunicationproductsofferedbySolarEdgearesupported.
Ethernet
EthernetisusedforaLANconnection.ForconnectioninstructionsrefertoCreatinganEthernet(LAN)
Connectiononpage55.
RS485
RS485isusedfortheconnectionofmultipleSolarEdgedevicesonthesamebusinamaster-slave
configuration.RS485canalsobeusedasaninterfacetoexternaldevices,suchasmetersandthirdparty
dataloggers.
l RS485-1:Enablestheconnectionofmultipledevices(inverters/CommercialGateway)overthe
samebus,suchthatconnectingonlyonedevicetotheInternetissufficienttoprovide
communicationservicesforallthedevicesonthebus.
l RS485Plug-in:TheRS485Plug-inprovidesanadditionalRS485portforthe
inverterforenhancedcommunications.Thekitcontainsamodule,whichis
installedonthecommunicationboard,andhasa3-pinRS485terminalblock.
Thiskitisprovidedwithaninstallationguide,whichshouldbereviewedpriorto
connectionsee,https://www.solaredge.com/sites/default/files/RS485_
expansion_kit_installation_guide.pdf
ForconnectioninstructionsrefertoCreatinganRS485BusConnectiononpage58.
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
52
Chapter 6: Setting Up Communication