Datasheet

SolarEdge Home Hub Inverter
For North America
SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US
(1)
SE3800H-US
SE7600H-US
SE-11400H-US
UNITS
OUTPUT AC ON GRID
Rated AC Power
3800 @ 240V
3300 @ 208V
7600
11400 @ 240V
10000 @ 208V
W
Maximum AC Power Output
3800 @ 240V
3300 @ 208V
7600
11400 @ 240V
10000 @ 208V
W
AC Frequency Range (min - nom - max)
59.3 - 60 - 60.5
(2)
Hz
Maximum Continuous Output Current @ 240V
16
32
47.5
A
Maximum Continuous Output Current @ 208V
16
-
48.5
A
GFDI Threshold
1
A
Total Harmonic Distortion (THD)
<3
%
Power Factor
1, adjustable -0.85 to 0.85
Utility Monitoring, Islanding Protection,
Country Configurable Thresholds
Yes
Charge Battery from AC (if allowed)
Yes
Typical Nighttime Power Consumption
<2.5
W
OUTPUT AC BACKUP
(3)
Rated AC Power in Backup Operation
(4)
3800
7600
10300
W
7600*
10300*
AC L-L Output Voltage Range in Backup
211 - 264
Vac
AC L-N Output Voltage Range in Backup
105 - 132
Vac
AC Frequency Range in Backup (min - nom - max)
55 - 60 - 65
Hz
Maximum Continuous Output Current in Backup
Operation
16
32
43
A
32*
43*
GFDI
1
A
THD
<5
%
OUTPUT SOLAREDGE HOME EV CHARGER AC
Rated AC Power
9600
W
AC Output Voltage Range
211
264
Vac
On-Grid AC Frequency Range (min - nom - max)
59.3
60
60.5
Hz
Maximum Continuous Output Current @240V
(grid, PV and battery)
40
Aac
INPUT DC (PV AND BATTERY)
Transformer-less, Ungrounded
Yes
Max Input Voltage
480
Vdc
Nom DC Input Voltage
380
Vdc
Reverse-Polarity Protection
Yes
Ground-Fault Isolation Detection
600kΩ Sensitivity
INPUT DC (PV)
Maximum DC Power @ 240V
7600
15200
22800
W
15200*
22800*
Maximum DC Power @ 208V
6600
-
20000
W
Maximum Input Current
(5)
@ 240V
10.5
20
31
Adc
20*
31*
Maximum Input Current
(5)
@ 208V
9
-
27
Adc
Max. Input Short Circuit Current
45
Adc
Maximum Inverter Efficiency
99.2
%
CEC Weighted Efficiency
99
99 @ 240V
98.5 @ 208V
%
2-pole Disconnection
Yes
* Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx.
(1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x.
(2) For other regional settings please contact SolarEdge support.
(3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid.
(4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated.
(5) A higher current source may be used; the inverter will limit its input current to the values stated.