Installation Guide

SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US Units
Revenue Grade Data, ANSI C12.1 Optional
1
Rapid Shutdown NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed
2
STANDARD COMPLIANCE
Safety UL1741, UL1699B, UL1998, CSA 22.2
Grid connection standards IEEE1547
Emissions FCC part15 class B
RoHS Yes
INSTALLATION SPECIFICATIONS
AC output conduit size / AWG range ¾” minimum / 16-6 AWG
DC input conduit size / # of strings / AWG
range
¾” minimum / 1-2 strings / 16-6 AWG
Dimensions (H x W x D)
21 x 12.5 x 7.2 /
540 x 315x 184
in/mm
Dimensions (H x W x D) with Safety Switch
30.5 x 12.5 x 7.2 /
775 x 315 x 184
in/mm
Weight 44.7 / 20.2 47.7/21.7 lb/kg
Weight with Safety Switch 51.2/ 23.2 54.7/24.7 lb/kg
1
Revenue grade inverter P/N: SExxxxA-US000NNR2 (for SE7600 inverter: US002NNR2)
2
Rapid shutdown kit P/N: SE1000-RSD-S1
Appendix B: Technical Specifications
SolarEdge-Installation Guide MAN-01-00002-4.0
99