Connecting the Strings to the Safety Switch
StringsmaybeconnectedinparalleltothetwoDCinputpairsoftheswitch.Ifmorethantwo
stringsarerequired,theycanbeconnectedinparallelusinganexternalcombinerboxbefore
connectingtotheswitch.Whenconnectingmultiplestrings,itisrecommendedtorun
separatecircuitstotheSafetySwitchortopositionthecombinerboxneartheswitch.This
simplifiescommissioningbyallowingtestingandservicingneartheinverter.
To connect the strings to the safety switch:
1. Strip5⁄16''(8mm)oftheDCwireinsulation.
2. InserttheDCconduitintotheDC-sideknockoutthatwasopened.
3. Equipmentgrounding:ConnecttheDCequipmentgroundconductortotheequipment
groundingterminalblockintheSafetySwitch.
NOTE
Functional Electrical Earthing of DC-side negative or positive is prohibited because the
inverter has no transformer. Earthing of module frames and mounting equipment
(equipotential bonding) is required per NEC.
4. ConnecttheDCwires:
CAUTION!
Ensure that the Plus (+) wire is connected to the + terminal and that the Minus (-) wire is
connected to the Minus (-) terminal connector.
Veillez à ce que le câble Plus (+) soit connecté au terminal + et que le câble - soit connec
au connecteur terminal.
NOTE
If more than two strings are connected each should be properly fused on both DC+ and
DC- according to NEC690.35(B).
NOTE
SolarEdge's fixed input voltage architecture enables the parallel strings to be of different
lengths. Therefore, they do not need to have the same number of power optimizers, as
long as the length of each string is within the permitted range.
l For single phase 3-7.6kW inverters-ConnecttheDCwiresfromthePVinstallationto
theDC+andDC-terminalblocks,accordingtothelabelsontheterminals.Usea
standardstraight-bladedscrewdrivertoconnectthewirestothespring-clamp
terminals,asdescribedfortheACconnectionofsinglephase3-7.6kWinverters
(connect the AC grid to the Safety Switch – single phase 3-7.6kW inverters:onpage38).