Installation Guide

Step 3: Verifying Proper Operation
Afterthewake-uptimeisover,astatusscreensimilartothefollowingappearsonthe
inverterLCDpanel:
V a c [ v ] V d c [ v ] P a c [ w ]
2 4 0 . 7 3 7 1 . 9 2 3 4 9 . 3
P _ O K : X X X / Y Y Y < S _ O K >
. . . . . . . . . . . . . . . . . O N
1. Verifythefollowing:
l ThegreeninverterLEDissteadilylit.
l TheON/OFFindicatorontheLCDpanelreadsON.
l P_OK: XXX/YYY:Thereisaconnectiontothepoweroptimizersandatleastonepower
optimizerissendingmonitoringdata.Optimizerssendtelemetriesinafrequencyofup
to10minutes.Initiallyafterpairing,bothXXXandYYYvaluesshow000andthevalues
increaseaspairedpoweroptimizersarereported.
NOTE
It may take up to 20 minutes for all power optimizers to transmit their telemetries and to be
counted on the LCD screen.
l S_OK appears,iftheinverterisconnectedtotheSolarEdgemonitoringportal.
l Vac [V]specifiesthemeasuredgridACoutputvoltage.
l Vdc [v] :SpecifiestheDCinputvoltage,whichshouldequalthesumoftheoutput
voltagesofallmodules(andshouldbewithintheoperatingrangeoftheinverter).
l Pac [W]specifiesthetotalACoutputpowerproduced.
2. Takenoteoftheserial#ontheinverterlabelusingthedetachable2Dbarcodestickeron
eachdevice.ThisinformationisusedintheSolarEdgemonitoringportaltoidentifythis
inverterandisneededtoopenanewsiteinthemonitoringportal.
YourSolarEdgepowerharvestingsystemisnowoperational.
Chapter 5: Commissioning the Installation
SolarEdge-Installation Guide MAN-01-00002-4.0
47