Installation Guide

CAUTION!
The gland includes a rubber waterproof fitting, which should be used to ensure
proper sealing.
Le cote interne du gland contient une rondelle qui doit être utilisée pour une bonne
étancheïté.
3. Removetheplasticsealfromthelargeopeningthathasacutintherubberfitting.
4. RemovetherubberfittingfromtheglandandinserttheCAT5/6cablethroughthegland
andthroughtheglandopeningintheinverter.
5. Pushthecableintothecutopeningoftherubberfitting.
Figure 35: Cable glands and rubber fitting
CAT5/6standardcableshaveeightwires(fourtwistedpairs),asshowninthediagrambelow.
Wirecolorsmaydifferfromonecabletoanother.Youcanuseeitherwiringstandard,aslong
asbothsidesofthecablehavethesamepin-outandcolor-coding.
RJ45 Pin #
Wire Color
1
10Base-T Signal
100Base-TX Signal
T568B T568A
1 White/Orange White/Green Transmit+
2 Orange Green Transmit-
3 White/Green White/Orange Receive+
4 Blue Blue Reserved
5 White/Blue White/Blue Reserved
6 Green Orange Received-
7 White/Brown White/Brown Reserved
8 Brown Brown Reserved
1
The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends on the
switch capabilities.
Chapter 7: Setting Up Communication
SolarEdge-Installation Guide MAN-01-00002-4.0
75