User's Manual

8
2. Feed the Ethernet CAT5 Cable through the Feedthrough Body (pre-
installed on the enclosure at the factory) and insert the RJ-45 connector to
the female connector inside the enclosure.
3. Install the Compression Nut and hand tighten until the cable resists
slipping when gently pushed or pulled. Lightly wrench-tighten, being
careful not to overtorque the Compression Nut.
The unit with properly installed feedthrough appears as follows:
Notes:
(a) Removal of the RJ45 plug from the radio can be aided by a thin screwdriver,
or opened paperclip. Care must be taken not to damage the Feedthrough Body
or RJ45 plug.
(b) The total combined length of the Ethernet cables between the radio and
your network access device (hub/switch/PC) must not exceed 300 feet.
(c) Once mounted in a permanent location, additional weatherproofing tape
(included) should be applied around the assembled fitting to further enhance
durability.
(d) In order to maintain FCC compliance, the use of shielded CAT5 cable is
required.
C. BRACKET PREPARATION
The SkyWay mounting bracket is pre-assembled at the factory for ease of
installation.