C. UsingtheFieldTransmitterviaInfraRedConnection(IR)
Thefieldtransmitterisabletocommunicateviainfraredwithalltypesofoldornewgeneration
TBOS™controlmodules.Certainexclusivefunctionsareonlyaccessiblewhenthefieldtransmitteris
connectedtoaTBOSII™IRcontrolmodule,i.e.:
Waterbudget,
Assignmentofastationtoseveralprograms,eachwithadiff
erenttime,
Stationtest,
1to31daycyclicalirrigationschedules(1to6daysfortheTBOSmodel),
CustomisationofTBOSIImoduleanditsstationsnames,
Savingofprograminthecontrolmodule
Thefieldtransmittercanalsoaddthe"RainDelay"fun
ctiontoallTBOS™controlmodules.Ithas6
memorystorageareasthatcanstore6differentpro grams:3arededicatedtooldmodelTBOS™
modulesandthe3otherstotheTBOSII™modules.Italsoallowstocancelallorindividualprograms
containedinanyTBOS™module(TB
OS™modulereset).
1. ProgrammingTBOSII
TM
FieldTransmitter
Beforeprogrammingprocess,youMUSTconnectthefieldtransmitterinfraredcordonthe
TBOS
TM
/TBOSII
TM
ControlModuleInfraredconnector.
TowakeuptheFieldTransmitter,pressHomeduring2sec.
PresstheOKkey,select"TBOSIRinfrared"withÕÖandconfirmbypressingOKinorderto
readtheprogramdatacontainedinyourTBOS™ControlModule.Thereadingofprogram
datacantakebetween2and12secondsaccordin
gtotheTBOS™moduleversion(oldor
new).
Thefirstinfraredwelcomescreenindicatesthestatusofthevariousexternalitems(TBOS™module
sensororbattery),ON/OFFstate,oftheWaterbudgetorthewateringoperationinprogress(TBOS
II™only).
CreatingIrrigationSchedulesWateringDays
Thefieldtransmittercontains3independentprograms(A/BandC).Separatewateringdays,start
timesandwateringruntimescanbesetforeachprogram.
Note
:astationcanbeassignedtoonlyoneprogram,eitherA,BorCinthecaseofanoldgeneration