Specification Sheet

80
HR160H
Specications
Polypropylene HRV Core: cross-ow that transfers sensible heat
Typical Airow Range: 30-160 CFM
Duct Connections: Four (4) 6” dia. ISF double collar system
Number Motors: Two (2) PSC variable speed backward curved
V Hz Phase Amperage
120 60 Single 1.5 A / 142 watts
Exchange surface: 85 ft
2
Defrost type: Evacuation
Filters: Two (2) Fiberbond washable
Drain Connection: 1/2”
DuoTrol: Integrated Balancing System
Weight: 43 lbs (unit), 49 lbs (in carton)
Dimensions: 29-1/2” W x 22-1/2” L x 11-3/8” H
Options:
HRT-3 - Push Button Timer
HRRD-1 - Dehumidistat
HRRD-3P - Dehumidistat
Dimensions
Minimum Clearance Data
Supply
Temperature
Net Air Flow
Power
Consumed
(Watts)
Sensible
Recovery
Efciency
Apparent
Sensible
Effectiveness
°F °C CFM L/s
32 0 65 31 72 66 75
32 0 83 39 80 63 72
32 0 107 50 94 60 67
-13 -25 76 36 72 56 73
Energy Performance (Heating)
External Static
Pressure
Net
Air Flow
Gross Air
Flow
Supply
Gross
Air Flow
Exhaust
Pa in. w.g. L/s CFM L/s CFM L/s CFM
25 0.1 91 193 91 194 103 217
50 0.2 84 178 85 179 95 201
75 0.3 77 163 77 163 86 183
100 0.4 71 150 71 151 80 169
125 0.5 63 133 63 134 71 152
150 0.6 57 120 57 121 66 138
175 0.7 51 109 51 109 57 121
Ventilation Performance
21.5"
545.9 mm
6"
152.5 mm
23.9"
606.3 mm
2.8"
72.4 mm
5"
126 mm
5.5"
140.5 mm
11.7"
297.6 mm
Front View
Top View
15"
381 mm
3"
76.2 mm
12"
305 m
m
3"
76.2 mm
15"
381 mm
Minimum plug
clearance
Minimum clearance for drain fitting
Recomended minimum clearance
for “P” trap of 10" (254 mm)
WallWall
Minimum door clearance
Front View
Top View
MODEL HR