Floor Area
(sq. ft.)
Number of Bedrooms
0-1 2-3 4-5 6-7 >7
CFM Requirements
<1500 30 45 60 75 90
1501-3000 45 60 75 90 105
3001-4500 60 75 90 105 120
4501-6000 75 90 105 120 135
6001-7500 90 105 120 135 150
>7500 105 120 135 150 165
Local Exhaust Requirement
A local mechanical exhaust system shall be
installed in each kitchen and bathroom:
Kitchens: 100 CFM intermittent or 5 ACH
continuous (based on kitchen volume)
Bathrooms: 50 CFM intermittent or 20 CFM
continuous
Use a PC Premium Choice Bath Fan in each
bathroom to meet the ASHRAE 62.2 Local
Exhaust Requirement. Please note each
bathroom fan counts towards meeting the
ASHRAE 62.2 Whole Building Requirement.
Whole Building Requirement
Required ventilation is based on the size of the
house and number of expected occupants.
1. Calculation:
Required Rate = Floor Area / 100 + (Number
of Bedrooms + 1) x 7.5
If the number of occupants exceeds the
assumed 2 persons for the rst bedroom
and 1 for each additional room, increase
the ventilation rate as follows: Number of
additional occupants x 7.5 CFM
2. Use the Whole Building Ventilation
Requirements CFM chart from the ASHRAE
62.2 Standard:
ASHRAE 62.2
ASHRAE 62.2
The ASHRAE 62.2 Standard applies to all residential spaces that are “intended for human
occupancy” in single family homes and multi-family structures up to three stories. These spaces
include living rooms, bedrooms, kitchens, bathrooms, hallways, closets, store rooms, laundry
rooms, garages, and basements.
There are two components of the ASHRAE 62.2 standard that relate to ventilation fans: Whole
Building Ventilation & Local Exhaust.