Please read Owner’s Manual carefully before operating the unit.
Main technical parameter of RT-135 Capability Operating Capabilities: Cooling Operating capabilities: Heating Unit Btu/h W A Btu/h W A CFM Cooling Capacity Watts Rated Full Load Current Heating Capacity Watts Rated Full Load Current Air Flow Volume Power Supply F F dB(A) dB(A) ounce Operational Range-Cooling Operational Range-Heating Noise Level Inside The Room Outside The Room Refrigerant / Amount Top Mount Unit Indoor Unit Assembled Top Mount Unit Dimensions Indoor Unit Net Weight lbs In In RT
Use RT-135 series air-condition have the capability of cooling / heating / ventilation and dehumidification and contain the character of resisting shake attrition and high-dependability. It can be used for applications such as RV units, trucks & vans, small-scale shipping vehicles & farm equipment.
Remote device Operation through the control panel or remote device Through the control panel in the room, user can control all functions of the air-conditioner. The parts of control contain the following functions: 1. Switch The air-conditioner can be started or stopped by the button “ON/OFF”. The indicator lamp “POWER” in the upper left corner is lighted when air-conditioner is running. 2. Choose button “MODE” This button confirms the working status of the air-conditioner.
The scheme of refrigeration system CONDENSER EVAPORATOR FAN COMPRESSOR THROTTLE 4
SENSOR1 WAT2 SENSOR2 FU3 5 WH FAN WH ~ MF 3 2 C2 N N N KA1 N T R RE COMP YE + GR ~ GR C1 KA1 MCS L C BL L TRANS-IN TRANS-OUT FU2 YE + GR YE RE 20AWG H-FAN HEAT on BL L-FAN CONTROL PANEL WAT1 com 4 OPERATE PANEL +5V GND A B C G DAT CLK REC KEY HEATER 12AWG PT 1 PE 12AWG L 110VAC N 60HZ PE Schematic circuit diagram
Cautions 1. In any case the compressor will restart 3 minutes after power failure 2. The air-conditioner adopts three core plugs: Modification will void warranty 3. Working voltage of the air-conditioner must keep within the range of 115VAC±10. If the voltage is too high or low will lead to damage of the compressor. 4. The normal working environment temperature of the air conditioner is: 0F to115F Maintenance and Safeguard It will keep at maximum performance ratings if you perform routine maintenance.
No heat The fan doesn’t operate Unusual shaking sound or heavy 1. Power is off. 2. Set temperature is in improper position 3. Connector has fallen off. 4. Heater is defective 5. Fuse is open. 6. Control panel is not working. Check the circuit Adjust the set value 1. Control panel is faulty. 2. The capacitor of fan defective. 3. Fan defective. Change the panel. Change the capacitor. 1. Installation of the air-conditioner too gradient. 2. Fan touches with other hardware. 3.
3. You must make mounting hole on indoor installation frame align with the hole on the top of the air-conditioner and tightly connect with 4-M10 special screw. 4. Install canvas-pipe You must make the flange of the canvas-pipe align with air outlet of the top of air-conditioner and connect them with screw, gasket, spring gasket and nut.
5. Prepare installing of indoor equip: Disassemble the indoor equip. 6. Install the indoor unit a) You must install the main of indoor tunnel and installation frame with four ST4.2X16 screw. Caution: It can be rotated from +90°to -90°. b) Installing the canvas pipe underparts You must put into metal flange from canvas pipe under part and tightly nip main vent-pipe and connect with ST4.2X16 screw. The surplus part is cut out. c) Install covers board of vent-pipe and indoor main cover board.
Check 1. Check the complete installing manual to make sure unit is installed correctly and safe 2. Switch on the power, operate the air conditioner according to above methods. If it runs improperly, for example abnormal noise, running current too high or no temperature, please check owner’s manual.
3. Clean up the installing rubbish and restore decoration to original decor.
Warranty LIMITED WARRANTY Soleus International Inc. warrants the accompanying Soleus Air RT-135 Roof Top Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of labor and parts specified below. PARTS 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER COMPONENTS This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance.