ADDRESS: Soleus International, Inc. 20035 E. Walnut Dr. N., City of Industry, CA 91789 WEBSITE: www.soleusair.com TEL: (888) 876-5387 SG-DEH-70EP-2 '3 (3 Portable Dehumidifier with External Pump Operating Instructions V.
TABLE OF CONTENTS Package Contents .............................................2 Warranty ...........................................................2 Safety Instructions ............................................3 Electrical Requirements ..................................4 Installation ........................................................4,5 Key Features ....................................................5 Control Panel ...................................................6 Water Disposing Options……….
NOTES _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ ________________
ELECTRICAL REQUIREMENTS OBSERVE ALL LOCAL CODES AND ORDINANCES. RECOMMENDED GROUNDING METHOD For your personal safety, this appliance must be grounded. This appliance has a power supply cord with a 3-prong grounded plug. To minimize possible shock hazard the cord must be plugged into a matching grounded electrical outlet that complies with the latest edition of the National Electrical Codes and all local codes and ordinances. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG.
TROUBLESHOOTING ERROR CODES CHOOSING THE PROPER LOCATION AUTOMATIC SHUT OFF • When the bucket is full, or when the bucket has been removed, the compressor will automatically stop. The fan will continue to run to dehumidify for 3 minutes. Then the Bucket Full indicator will flash and you will hear a ten second audible alarm. • The bucket must be placed in the proper position for the dehumidifier to work.
TROUBLESHOOTING (Cont.) CONTROL PANEL (7) (8) (9) (10) (11) (12) (13) Problem Dehumidifier runs too much (4) (5) (3) (2) (1) Solutions The area to be dehumidified is too large. The capacity of your dehumidifier may not be adequate for the room size. Doors and windows are open. Close all doors and windows to the outside. Frost appears on the coils The dehumidifier has recently This is normal. Frost will usually disappear been turned on or the room within 60 minutes.
WATER DISPOSING OPTIONS TROUBLESHOOTING Problem Possible Causes Solutions Dehumidifier does not start. The dehumidifier is unplugged. Make sure the dehumidifier’s plug is pushed completely into the outlet. The fuse is blown / circuit breaker is tripped. Check the house fuse / circuit breaker box and replace fuse or reset breaker. Dehumidifier has reached the user set humidity level or the bucket is full. The dehumidifier automatically turns off when either condition occurs.
INSTALLING THE GRAVITY DRAIN HOSE Option 2: GRAVITY DRAIN HOSE CARE AND MAINTENANCE CLEANING THE AIR FILTER After 250 hours of operation the FILTER RESET indicator will light up to remind you to clean and change the air filter. Step 1: Open the drain connector door. (Fig. 6) WARNING • Disconnect power supply cord from re- ceptacle before performing any maintenance. It is recommended to periodically check the filter for excess dirt even if the FILTER RESET indicator is off. (FIG.
INSTALLING THE GRAVITY DRAIN HOSE USING THE PUMP NOTE: Make sure the drain hose is lower than the horizontal plane of the drain on the dehumidifier as seen in the illustration below. Drain hose should be as short as possible and all kinks in the drain hose should be eliminated for proper pump operation. Step 4: Insert the drain hose onto the drainage joint so that it is fully seated. (Fig. 9) 3ft. Dehumidifier Drain Hose (FIG. 9) (FIG.
INSTALLING THE EXTERNAL PUMP INSTALLING THE EXTERNAL PUMP Step 4: Insert pump drain hose onto pump connector until it is fully seated. Secure hose by pushing small clamp forward towards the pump. (Fig. 14) OPTION 3: EXTERNAL VERTICAL PUMP INSTALLING THE EXTERNAL PUMP Step 1: To install Dehumidifier Drain Hose, refer to Gravity Drain Using Dehumidifier Hose instructions starting on page 9. Step 2: For optimal operation, it is recommended that the pump is placed on a flat and level location.