Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-18-ID / KFHHP-18-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.
TABLE OF CONTENTS USE AND MAINTENANCE……………………………..…………………………………….....1-14 Precautions on Use …………………………………………………………………..……………1-3 Specifications and Technical Data…………………………………………………………………...4 Instructions of Use…………………………………………………….…………………….……….5 Description of Air Conditioner Components………………………………………………...………6 Remote Control Operation…………………………………………………………………………7-8 How to Insert Batteries…………………………………………………….…………………………9 Cleaning and Maintenance…………………………………………....……………...………….
Use and Maintenance ◆Precautions on Use Carefully read the following precautions before use Warning ★In case of malfunction (e.g. burnt ★To avoid electric shock. Never smell), cut off the power supply immediately and then contact the Authorized Service Center (626-8201436). operate the unit with wet hands. ★Do not cut or use damaged power cords and control lines. The malfunction continues, the air conditioner may be damaged. ★There is a possibility of electric shock or fire.
◆Precautions on Use ★Grounding: The unit must be properly grounded. ★Set the room temperature appropriately. The difference between indoor and outdoor temperature shall be 40 °F. ★Close all doors & windows for efficient operation. ★Never block the air inlet or outlet of indoor and outdoor unit. ★To avoid the possibility of fire. Never store chemicals or flammable items within 3.28 feet of the unit. Otherwise it may cause fire or explosion.
◆Precautions on Use ★Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the direction of air flow. ★To avoid injury or damage, never stick your fingers or any other object into the unit. ★To avoid harm to your pets or plants, never direct the ★To avoid damage or electric shock, never spray liquid onto the unit.
◆Specifications and Technical Data Model KFHHP-18-ID / KFHHP-18-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 18000 / 5300 (1400-6000) Heating capacity(BTU/hr) & (Watts) 20000 / 6000 (1100-7000) Rated voltage 208-230V~ Rated Frequency 60Hz Cooling/Heating rated current(A) 10.6/10.6 Cooling/Heating rated power(W) 2440/2440 Cooling/Heating power input(W) 1350/1800 SEER 13.25 EER/COP(W/W) 3.93/3.22 HSPF 8.5 Recycling Air Volume(m3/h) 800 Factory Charge 410A (lbs.
◆Instructions for Use Principle and Special Functions during Cooling Mode Principle: The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temperature. Anti-freeze Function: If the air conditioner is running under low-temperature cooling mode, frost will appear on the surface of indoor heat exchanger.
◆Description of Air-Conditioner Components (1) Front Panel (2) Guide Louver (3) Remote Sensor (4) Wall Pipe (5) Wrapping Tape (6) Drainage hose (7) Connection pipe -6-
◆Remote Control Operation Function-Remote control Note: • • • Don't drop the remote control. Don't place the remote control in a location exposed to direct sunlight. When the unit is restarted after stopped, it will automatically resume its last running mode, and the outdoor unit will start there after. MODE Button: TEMP+ TEMP- Button: When the unit is turned on, press this button. The AUTO, COOL, DRY, FAN or HEAT mode can then be selected.
◆Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. ON/OFF Button SWING Button: Press ON. Press OFF. Press once to have louvers swing [oscillate]. Press twice in one second the panel light will turn on. Press twice again and the light will turn off. T-ON Button. When pressing this button once, enter into T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min.
◆How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (Two AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • • • • Don’t mix different batteries. Remove batteries when not in use for a longtime. The batteries can be used for about one year. Keep remote at least 3.28 feet from TV’s and other electronic devices.
◆Cleaning and Maintenance • Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might occur. • Liquids on the air conditioner may cause the risk of electric shock. Make sure not to spray wash your air conditioner in any case. • Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth or wet cloth soaked with neutral detergent to clean the air conditioner cabinet).
◆Cleaning and Maintenance ③ Installing the air filter Mount the air filter in the direction of the arrows. Then, clamp the cover of front panel securely. Check before Seasonal Use ① Check the air inlet/outlet on indoor and outdoor units for any blockage. ② Check the grounding cable for reliability. ③ Check the batteries of remote control for replacement. ④ Check the mounting frame of outdoor unit for damage. If damaged, please contact the Authorized Service Center.
◆Trouble-Shooting Do not repair by yourself. Incorrect repair may cause electric shock or fire, so please contact the Authorized Service Center for professional repair. Fault Cause Analysis Air conditioner does not run upon immediate restart after a stop. To protect the air conditioner upon immediate restart after a stop, the microcomputer control will delay the unit for 3 minutes before the air conditioner will run. Air conditioner blows out a bad odor when it is initially started.
◆Trouble-Shooting Fault Cause Analysis Air conditioner does not run. • Power failure? • Circuit protection device tripped? • The voltage is too high or too low? Refer to Page 15). (To be tested by ( professional technicians). • Timer function is correctly used? Refer to Page 7). ( Air conditioner is poor in cooling (or heating) effect. Refer to Page 7) • Is temperature setting proper? ( • Is the air inlet or outlet of outdoor unit blocked? Refer to Page • Is the air filter clogged by dust? ( 10).
◆Trouble-Shooting Fault Cause Analysis No air blows out from indoor unit. • When the temperature of indoor heat exchanger is low during heating process, the indoor unit will stop blowing to prevent blowing of cold air (within 3 minutes). • Under dehumidify mode, the fan of the indoor unit might be stopped to prevent evaporation of condensing water and inhibit the rise of temperature. Moisture exists on outlet grill.
Installation Services ◆Precautions on Installation Important Caution 1. 2. 3. The air-conditioning unit must be installed by professional technicians in accordance with the state and local codes. Contact the local installation and service agency before installation. For relocation of the air conditioner to another position, please contact the local Authorized Service Center. Basic Requirements for Installation Position Installation at the following places may cause failure of the air conditioning unit.
◆Precautions on Installation 4. 5. Ensure safe grounding and the grounding wire shall be connected with the special grounding equipment of the building and must be installed by professional technicians. In the fixed line there must be an electrical leakage protection switch and an air switch with sufficient capacity. The air switch shall also have the magnetic tripping and thermal tripping functions to achieve protection of both short-circuit and overload.
◆Installation Dimension Drawing - 17 -
◆Install Indoor Unit Installing Wall-Mounting Frame 1. 2. 3. Level with plumb line or spirit level. As the drain outlet is on left side, it is better that the left side shall be lower when adjusting the wall-mounted board. Use screws to secure the wall-mounting frame on the wall. After installation is completed, manually pull the wall-mounting frame to check if it is secured.
◆Install Indoor Unit Notes: If the connecting cable is not long enough, please contact your distributor for a piece of special cable with sufficient length. No joints are allowed in the middle of the cable. • • • • • Be sure to connect the cable correctly. Incorrect connection will cause fault to some electrical parts. Tighten the terminal screw. After tightening the screw, gently pull the cable for tightness. Incorrect connection of grounding cable might cause electric shock.
◆Install Outdoor Unit Power Cable Connection 1. 2. 3. 4. 5. Remove the handle at the right side plate of the outdoor unit (one screw). Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and make the connection. The fitting line distributing must be consistent with the indoor unit. Use cable clamp to make the cable connection cable. Confirm the fitting lines are properly installed. Install the handle (fixed by one screw).
◆Install Outdoor Unit Check Items After Installation Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the refrigerant gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit sufficient? May cause condensation and water dripping Is the drainage smooth? May cause condensation and water dripping Does the power supply voltage accord with the rated voltage specified o
Electrical Schematic Diagram ◆Electrical Schematic Diagram (Indoor Unit) - 22 -
◆Electrical Schematic Diagram (Outdoor Unit) - 23 -
Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-18-ID/KFHHP-18-OD) to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of parts specified below. 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER COMPONENTS This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance.